Power, Control & Fibre Optic Cables Supplier UAE | Gasify Middle East
PRODUCTS · CABLES · POWER, CONTROL & FIBRE OPTIC · UAE

Supplying High-Performance Power, Control & Fibre Optic Cables

Gasify Middle East supplies HV and MV XLPE power cables, LV XLPE and PVC power cables, multicore control cables, panel wire, flexible and VFD cables, instrumentation and thermocouple cables, fire-performance cables and fibre optic cables from Abu Dhabi and Dubai. Cables to IEC, BS and IS standards, in copper and aluminium, supplied against your cable schedule with per-drum test reports.

Built for project procurement: we match each cable to voltage grade, conductor, armour, sheath and fire performance, confirm sources against your project specification, and support ADNOC, Saudi Aramco and other client-specification enquiries across the UAE, GCC, Middle East, Africa and South Asia.

IEC 60502-1IEC 60502-2BS 5467IS 7098IEC 60228IEC 60332IEC 60331IEC 60794
01 / CABLE RANGE

Cables for power, control and communication.

From MV XLPE cables to panel wire, instrumentation pairs and fibre optics, sourced against voltage grade, construction, fire performance and project specification.

HV & MV Power Cables — Gasify Middle East cable supplyCABLES · 01
01PROJECT SUPPLY

HV & MV Power Cables

XLPE insulated, screened medium and high voltage cables from 3.6/6 kV to 18/30 kV (up to 33 kV), single and three core, armoured or unarmoured.

3.6/6 – 18/30 kVXLPECu / Al
LV XLPE Power Cables — Gasify Middle East cable supplyCABLES · 02
02PROJECT SUPPLY

LV XLPE Power Cables

0.6/1 kV (1.1 kV) XLPE power cables, armoured or unarmoured, in copper or aluminium, for distribution and plant supply.

0.6/1 kVXLPE / SWAUp to 1000 mm²
LV PVC Power Cables — Gasify Middle East cable supplyCABLES · 03
03PROJECT SUPPLY

LV PVC Power Cables

PVC insulated and sheathed power cables for general low voltage wiring and distribution where XLPE is not required.

PVC / PVC0.6/1 kVArmoured / unarmoured
Multicore Control Cables — Gasify Middle East cable supplyCABLES · 04
04PROJECT SUPPLY

Multicore Control Cables

Multicore control cables with numbered or coloured cores for control rooms, switchgear and motor control centres.

2 – 61 core1.5 / 2.5 mm²Screened
Panel Wiring, Flexible & VFD Cables — Gasify Middle East cable supplyCABLES · 05
05PROJECT SUPPLY

Panel Wiring, Flexible & VFD Cables

Single core panel wire, flexible multicore cables and screened VFD cables for control panels, machinery and drives.

Panel wireFlexibleVFD screened
Instrumentation & Thermocouple Cables — Gasify Middle East cable supplyCABLES · 06
06PROJECT SUPPLY

Instrumentation & Thermocouple Cables

Pair, triad and multipair screened instrumentation cables, intrinsically safe blue sheath options, and thermocouple extension cables.

Pairs / triadsScreenedIS blue
Fire-Performance, Solar & Special Cables — Gasify Middle East cable supplyCABLES · 07
07PROJECT SUPPLY

Fire-Performance, Solar & Special Cables

FR, FRLS and LSZH cables, fire survival cables with glass mica tape, solar DC cables, mining, anti-termite and other special-purpose cables.

FRLS / LSZHFire survivalSolar DC
Fibre Optic Cables — Gasify Middle East cable supplyCABLES · 08
08PROJECT SUPPLY

Fibre Optic Cables

Single-mode and multimode, armoured and LSZH fibre optic cables with patch cords, connectors and accessories. See the dedicated fibre optic page.

OS2 / OM3 / OM4ArmouredLSZH
02 / SPECIFICATIONS

Cable specification tables by type and standard.

Typical supply ranges. Availability depends on type, size, conductor and quantity, and is confirmed for every RFQ.

CableStandardConstructionSize & ratingTypical use
MV XLPE cable, 3.6/6 to 12/20 kVIEC 60502-2; IS 7098 Part 2; BS 6622Cu or Al conductor, semi-conductive screens, XLPE, copper tape or wire screen, PVC / LSZH sheath35 to 1000 mm² single core; 35 to 400 mm² three corePlant and utility distribution, substations
MV XLPE cable, 18/30 kVIEC 60502-2; BS 7835; IS 7098 Part 2As above, with thicker insulation35 to 1000 mm² single core; up to 400 mm² three coreBulk power supply, solar and thermal power plants
Armoured MV cable, steel strip or wireIEC 60502-2; IS 7098 Part 2Galvanised steel strip or round wire armour over inner sheathThree core typicalDirect burial, trenches, mechanical protection
Single core MV cable, non-magnetic armourIEC 60502-2; IS 7098 Part 2Aluminium wire or strip armour to avoid eddy current losses on AC35 to 1000 mm²Single core runs on AC systems
Anti-termite / FRLS / LSZH sheath MV cableIEC 60502-2; client specificationSpecial sheath compound over armour or screenAs aboveTermite areas, enclosed spaces, tunnels
Extra high voltage cableIEC 62067 / client specificationXLPE, lead or aluminium laminate sheathOn enquiryTransmission above 33 kV on enquiry

State voltage grade (IEC or IS), standard, single or three core, conductor material and size, screen, armour, sheath type and drum length in the RFQ. Extra high voltage cables are sourced on enquiry.

CableStandardConstructionSize & ratingTypical use
LV XLPE cable, unarmouredIEC 60502-1; IS 7098 Part 1; BS 5467 (armoured)Cu or Al, XLPE insulation, PVC or LSZH sheath1.5 to 1000 mm² single core; up to 630 mm² multicoreDistribution cabling in ducts and trays
LV XLPE cable, armoured (SWA / strip)IEC 60502-1; BS 5467; BS 6724 (LSZH)Steel wire or strip armour over extruded inner sheath1.5 to 630 mm² multicoreDirect burial, plant and outdoor routes
Single core LV cable, non-magnetic armourIEC 60502-1; BS 5467Aluminium wire or strip armourUp to 1000 mm²Single core runs on AC circuits
LV PVC cable, unarmoured and armouredIEC 60502-1; IS 1554 Part 1; BS 6346Cu or Al, PVC insulation, PVC sheath1.5 to 630 mm²General wiring and distribution
LSZH low voltage cableBS 6724; IEC 60502-1; IEC 60754Cu or Al, XLPE, LSZH sheath1.5 to 630 mm²Hospitals, airports, metros and offshore
Sector-shaped multicore cableIEC 60502-1Shaped conductors give smaller overall diameterLarger sizes, multicoreSpace-limited trenches and ducts

Cores are laid up with a right-hand lay. State the core colour code (IEC 60502-1 or BS 5467) in the RFQ. See the Grades, Colours and Codes tab.

CableStandardConstructionSize & ratingTypical use
Control cable, XLPE or PVC, multicoreIEC 60502-1; IS 1554; BS 6346Cu stranded conductor, numbered or coloured cores, unarmoured or armoured2 to 61 core; 1.5 and 2.5 mm²Switchgear, MCCs, control rooms and signalling
Screened control cableIEC 60502-1; client specificationCopper tape or braid screen, drain wire2 to 61 coreNoise-sensitive control circuits
Armoured control cableIEC 60502-1; BS 5467SWA or strip armour with inner sheathAs aboveOutdoor and direct burial control wiring
FRLS / LSZH control cableIEC 60332-3; IEC 60754FRLS PVC or LSZH sheathAs aboveFire-sensitive installations
Power and control hybridManufacturer standardPower cores and control cores in one cablePer designCombined supply and control to equipment

State the number of cores, conductor size, screening, armour, sheath and core identification (colour or numbered) in the RFQ.

CableStandardConstructionSize & ratingTypical use
Single core panel wire (PVC)IEC 60227-3; IS 694Flexible or solid Cu conductor, PVC, 450/750 V0.5 to 400 mm²Control panel and switchboard wiring
Single core panel wire, high-temperatureIEC 60245; UL 758 (AWM)Cu, silicone, PTFE or cross-linked insulation0.5 to 16 mm²Hot enclosures and heater circuits
Flexible multicore cable (PVC)IEC 60227-5; IS 694Class 5 Cu, PVC insulation, PVC sheath, 300/500 V2 to 24 core; 0.5 to 6 mm²Light machinery and portable equipment
Flexible rubber cable (H07RN-F type)IEC 60245-4Class 5 Cu, rubber insulation and sheath, 450/750 V1.5 to 240 mm²Mobile equipment, cranes and temporary supply
Screened VFD / motor drive cableManufacturer standard; IEC 60502-1Symmetric cores, copper braid or tape screen, XLPE2.5 to 240 mm²Variable frequency drive to motor
Welding and trailing cableIEC 60245-6; IEC 60245-4Fine-wire Cu, rubber sheath10 to 120 mm²Welding sets and heavy portable loads
Cable ties, markers and glandsManufacturer standardAccessories for terminating and identifyingPer cablePanel termination and identification

State voltage rating, flexibility class, insulation material, colour and the temperature of the installation in the RFQ.

CableStandardConstructionSize & ratingTypical use
Instrumentation cable, individual and overall screenIEC 60502-1 (construction); EN 50288; client specificationCu, PVC or XLPE, twisted pairs or triads, Al-Mylar screen, drain wire, overall screen1 to 48 pairs; 0.5 to 1.5 mm²Analogue and digital field signals, DCS and SCADA
Armoured instrumentation cableAs above; BS 5467 armourSWA over inner sheathAs aboveOutdoor, direct burial and tray routes
Intrinsically safe (IS) instrumentation cableIEC 60079-14; client specificationBlue sheath, screened pairsAs aboveIntrinsically safe circuits in hazardous areas
Thermocouple extension and compensating cableIEC 60584-3; ANSI MC96.1Matched alloy conductors, types K, J, T, N, E; screenedPairs and multipairsConnects thermocouples to controllers
RTD / Pt100 cableIEC 60751; client specification3-wire or 4-wire Cu, screenedSingle and multi-elementTemperature sensing circuits
Fieldbus and data cableIEC 61158; Profibus, Foundation FieldbusSpecific impedance and shieldingPer bus typeFieldbus, Profibus and Modbus networks

State pair or triad count, conductor size, screen type, armour, sheath colour and any intrinsic safety or fire performance requirement in the RFQ.

CableStandardConstructionSize & ratingTypical use
FR PVC cableIEC 60332-1; IEC 60332-3PVC with flame-retardant additivePer base cableOpen plants where flame spread must be limited
FRLS PVC cableIEC 60332-3; IEC 61034FR PVC with reduced smoke emissionPer base cableEnclosed plants and buildings
LSZH / ZHFR cableIEC 60754-1 / -2; IEC 61034-2Polyolefin or EVA based sheath, no halogen, low smokePer base cableMetros, airports, hospitals and offshore
Fire survival cableIEC 60331; BS 6387 (C, W, Z)Glass mica tape over the conductor, LSZH sheathPer design; 2 to 61 coreEmergency lighting, alarms and shutdown circuits
Solar DC cableEN 50618; IEC 62930Tinned Cu, cross-linked insulation and sheath, UV resistant, 1.5 kV DC2.5 to 35 mm²Photovoltaic strings and DC runs
Mining and anti-termite cableClient specificationDouble armour, tinned copper wires, special additive in sheathAs specifiedMines and termite-prone areas
Oil and chemical resistant sheathManufacturer specificationPUR or special compound sheathOn enquiryHydrocarbon-exposed routes
Lead sheathed cableOn requestLead layer over beddingOn enquiryCorrosive and chemical environments

State the fire performance class, any smoke and halogen limits, and the environment (termite, oil, UV). Fire survival cables need fire-rated supports and glands to keep circuit integrity.

CableStandardConstructionSize & ratingTypical use
Single-mode fibre cable, OS2ITU-T G.652.D; IEC 60794Loose tube or tight buffer, armoured or unarmoured2 to 288 corePlant, pipeline and campus backbones
Multimode fibre cable, OM3 / OM4 / OM5IEC 60793-2-10; ISO/IEC 1180150/125 µm, tight buffer or loose tube2 to 144 coreControl buildings, data halls
Armoured and direct burial fibre cableIEC 60794-3-10Steel tape or wire armour, water blocked6 to 288 coreDirect burial and harsh routes
LSZH and fire-resistant fibre cableIEC 60754; IEC 60331-25LSZH sheath, optional fire-resistant layersPer constructionEnclosed areas and emergency circuits
Patch cords, pigtails and connectorsIEC 61754; IEC 61300LC, SC, ST, FC, MPO; UPC and APCPer cord lengthEquipment and ODF termination

See the fibre optic cables page for fibre types, construction, loss data and the link loss calculator.

Voltage grades (IEC and Indian Standard)

IEC grade (U0/U)IS gradeClass
0.6/1 kV1.1 kVLow voltage power, control
3.6/6 (7.2) kV3.8/6.6 kVMedium voltage
6/10 (12) kV6.35/11 kVMedium voltage
12/20 (24) kV12.7/22 kVMedium voltage
18/30 (36) kV19/33 kVMedium voltage, up to 33 kV

Core colour codes

Number of coresIEC 60502-1BS 5467
1Red or blackBrown or blue
2Red and blackBrown and blue
3Red, yellow, blueBrown, black, grey
4Red, yellow, blue, blackBlue, brown, black, grey
5Red, yellow, blue, black, green/yellowGreen/yellow, blue, brown, black, grey
6 and aboveNumbers printed on each coreNumbers printed on each core

Cable designation code (VDE-style)

ConstituentCode
Aluminium conductorA
Copper conductor(no letter)
XLPE insulation2X
PVC insulationY
Steel round wire armourW
Steel strip armourF
Double steel round wire armourWW
Double steel strip armourFF
Non-magnetic (aluminium) round wire armourWa
Non-magnetic (aluminium) strip armourFa
PVC outer sheathY

Example: A2XFY is an aluminium conductor, XLPE insulated, steel strip armoured, PVC sheathed cable. 2XWY is a copper conductor, XLPE insulated, steel round wire armoured, PVC sheathed cable.

Construction and ordering notes

ItemOptionsNotes
ConductorsPlain or tinned copper, aluminium; Class 2 stranded, Class 5 flexible; circular or shapedIEC 60228. Use tinned copper where sulphur fumes are present
InsulationXLPE (90 °C operating, 250 °C short circuit), PVC (70 °C), rubber, LSZH compoundsXLPE has higher current rating and short-circuit capability than PVC
Inner sheathExtruded PVC or LSZH (preferred) or tapedExtruded gives a better water barrier under armour
ArmourGalvanised steel wire or strip for multicore; aluminium wire or strip for single core ACSingle core AC cables need non-magnetic armour
Outer sheathPVC, FR, FRLS, LSZH, PE, PUR; black as standard, blue for intrinsically safe circuitsChoose for fire, UV, oil, chemical and termite exposure
Drum lengthStandard drums of 500 to 1,000 m depending on size; cut lengths and long drum lengths on enquiryState the drum length per route to limit joints
MarkingMetre marking, cable code, voltage, standard, manufacturer and yearPer the product standard and order
PackingWooden or steel drums, sealed ends, drum label with test report referenceExport packing to suit destination
03 / CABLE SELECTION GUIDE

Match the cable to the circuit.

A quick reference for common cable needs. Final selection follows the cable schedule, load, fault level, route and project specification.

Circuit or needCableStandardNotes
Supply to a substation or plant block at 6 to 33 kVMV XLPE screened cable (single or three core)IEC 60502-2; IS 7098-2Select voltage grade, fault level and screen size
Distribution to MCCs, motors and panels at 415 VLV XLPE armoured cableIEC 60502-1; BS 5467Size for load, voltage drop and fault level
Single core runs on AC systemsSingle core cable with non-magnetic armourIEC 60502-1 / -2Magnetic armour overheats from eddy currents
Direct burial or exposed outdoor routeArmoured cable with extruded inner sheath and tough outer sheathIEC 60502-1Specify anti-termite additive if needed
Enclosed spaces, tunnels, hospitals and offshoreLSZH power or control cableBS 6724; IEC 60754; IEC 61034Low smoke and no halogen acid gas
Open plants where flame spread must be limitedFR or FRLS PVC cableIEC 60332-3Smoke and halogen are not eliminated
Emergency lighting, alarm and shutdown circuitsFire survival cable with glass mica tapeIEC 60331; BS 6387Supports and glands must also be fire-rated
Control wiring between switchgear and control roomMulticore control cable, numbered coresIEC 60502-1Allow 10 to 20% spare cores
Inside a panel or enclosureSingle core panel wireIEC 60227; IS 694Colour code by function and use ferrules on ends
Motor fed by a variable frequency driveScreened symmetrical VFD cableManufacturer standardTerminate the screen 360° at both ends
Process signals from field instrumentsScreened instrumentation pairs, IS blue where intrinsically safeEN 50288; IEC 60079-14Segregate from power cables
Connecting thermocouplesThermocouple extension cable matched to the typeIEC 60584-3Use the same alloy type as the thermocouple
Long data and network linksFibre optic cable (single-mode)IEC 60794; ITU-T G.652See the fibre optic page for options

Factors that decide cable size and construction: maximum operating voltage, load current, fault level and clearing time, overload duty, route length and voltage drop, installation method and ambient or ground temperature, soil conditions, and fire performance. Use the voltage drop calculator on the electrical page for a first check of drop.

04 / SHORT-CIRCUIT RATING & CONDUCTOR WEIGHT

Validate fault current ratings and conductor metal prior to quoting.

Conductor short-circuit withstand for the cable size and fault duration, the minimum size for a given fault level, and the copper or aluminium weight.

I = k × A ÷ √t (k: Cu XLPE 143, Cu PVC 115, Al XLPE 94, Al PVC 76)
A min = I × √t ÷ k
Weight = area × density × cores (Cu 8.89, Al 2.70 g/cm³)

SHORT-CIRCUIT WITHSTAND OF THIS CONDUCTOR—kA
MINIMUM SIZE FOR THE FAULT CURRENT—
CONDUCTOR METAL PER KM (ALL CORES)0kg/km
CONDUCTOR METAL FOR THE LENGTH0kg

Adiabatic method for the phase conductor only, valid for fault durations up to about 5 seconds, with the k values of IEC 60364-5-54. It does not size the screen or armour, and the current rating, voltage drop and installation conditions must be checked separately. Metal weight excludes insulation, sheath and armour. Send the cable schedule for a quotation →

05 / ADNOC & SAUDI ARAMCO PROJECT SUPPLY

Procurement & Technical Compliance for ADNOC & Saudi Aramco Projects

Operators and EPC contractors define the cable standard, fire performance, testing and vendor requirements. We work to those documents.

SPECIFICATION REVIEW

From cable schedule to a compliant quotation.

Before quoting, we check the enquiry against the documents that drive cable compliance on NOC-linked projects.

  • Cable schedule, datasheet and route review, including voltage grade, conductor, armour and sheath
  • Client and company specification requirements, including ADNOC and Saudi Aramco documents where the project calls for them
  • Approved manufacturer or vendor list (AVL) requirements for the proposed source
  • FR, FRLS, LSZH, fire survival and special sheath clauses
  • Drum length, marking and test requirements
TEST REPORTS & DOCUMENTATION

Test records that travel with the drum.

Documentation follows the purchase order and the project specification, with drum-level traceability.

  • Routine test report for each drum
  • Type-test reports for fire, smoke and construction
  • Datasheet, certificate of conformity and drum label records
  • Third-party inspection coordination where the project requires it
  • Packing list and shipping documents compiled for the client's records
Important: Gasify supports procurement against ADNOC, Saudi Aramco and other client specifications. Product compliance, approved-source requirements and documentation are reviewed for each project, and Gasify does not represent an approval or vendor-registration status.
06 / STANDARDS & CODES

Standards in Every Cable We Deliver

LV POWER CABLES

IEC 60502-1 · BS 5467 · IS 7098-1

Cables for rated voltages from 1 kV up to 3 kV, including armoured types.

MV POWER CABLES

IEC 60502-2 · BS 6622 · BS 7835 · IS 7098-2

Cables for rated voltages from 6 kV up to 30 kV.

CONDUCTORS

IEC 60228 · IS 8130

Conductor classes, sizes and resistance.

WIRING & FLEXIBLE

IEC 60227 · IEC 60245 · IS 694

PVC and rubber insulated cables for up to 450/750 V.

FIRE PERFORMANCE

IEC 60332-1 · 60332-3 · 60754 · 61034

Flame propagation, halogen content and smoke density.

FIRE SURVIVAL

IEC 60331 · BS 6387

Circuit integrity under fire, categories C, W and Z.

INSTRUMENTATION

EN 50288 · IEC 60584-3 · IEC 60079-14

Screened pairs, thermocouple extension and intrinsically safe wiring.

SOLAR CABLES

EN 50618 · IEC 62930

DC cables for photovoltaic systems.

CURRENT RATING

IEC 60364-5-52 · IEC 60287

Selection of wiring systems and current-carrying capacity.

SHORT CIRCUIT

IEC 60364-4-43 · IEC 60949

Conductor withstand to fault current.

FIBRE OPTIC

IEC 60794 · ITU-T G.652

Optical fibre cables and fibre recommendations.

TEST REPORTS

Routine and type tests · Drum test records

Per the cable standard and the order.

07 / TESTING & DOCUMENTATION

Testing & Documentation Governance

Tests and documents depend on the product standard, purchase order and applicable project specification.

✓

Routine tests

Conductor resistance, voltage test and insulation resistance on every drum, to the cable standard.

✓

Sample and type tests

Construction, dimension, tensile and elongation tests on samples, and type-test reports for the design.

✓

MV tests

Partial discharge and high-voltage tests on screened medium voltage cables where specified.

✓

Fire & smoke tests

Flame propagation, halogen content, smoke density and fire-survival type-test reports for FR, LSZH and fire survival cables.

✓

Drum inspection & marking

Visual and metre-mark checks, end sealing and drum labels before dispatch.

✓

Inspection & documents

Third-party inspection and witnessing coordination, test certificates, packing list and shipping documents.

08 / APPLICATIONS

Mission-Critical Applications

01

Oil & gas plants

Power, control and instrumentation cables for process units, utilities and control rooms.

02

Refining & petrochemical

FRLS, LSZH and armoured cables for plants with dense cable trays.

03

Power generation & solar

MV cables, control cables and solar DC cables for power plants.

04

Substations & utilities

HV and MV XLPE cables for utility distribution and bulk supply.

05

Offshore & marine

LSZH, fire survival and special sheath cables for platforms and vessels.

06

Industrial & automation

Control, panel, flexible and VFD cables for machinery and drives.

07

Infrastructure & buildings

LV power, LSZH and fire survival cables for buildings, metros and airports.

08

Data & telecom networks

Fibre optic cables and copper control networks for plants and campuses.

09 / WHY GASIFY

Cable Procurement Engineered for Your Entire Scope

CATALOGUE-STYLE SUPPLY
  • Quotation against a size list, with armour, sheath and fire class left to the buyer
  • Wrong colour code, voltage grade or standard found after delivery
  • Cables, glands, lugs and trays quoted separately
  • Approved-source requirements discovered late in the process
CABLE PROCUREMENT WITH GASIFY
  • Cable schedule reviewed, with voltage, standard, conductor, armour and sheath matched before quotation
  • Test report, traceability and TPI requirements aligned with the order
  • Power, control, instrumentation and fibre cables consolidated with glands, lugs and trays
  • AVL and vendor requirements checked at quotation stage
01

RFQ response support

Send a cable schedule or BOQ and the procurement team reviews scope, constructions and documentation before quoting.

02

Established manufacturers, UAE coordination

Cables sourced from established manufacturers, with procurement and shipping coordinated from the UAE.

03

Drum lengths & phased supply

Drum lengths planned to the route to limit joints, with phased deliveries to match installation.

10 / CABLE SUPPLIER IN THE UAE

Power, control and fibre optic cable supplier in Abu Dhabi and Dubai.

Gasify Middle East Trading LLC is a UAE-based industrial supplier of electrical cables for oil and gas, petrochemical, power, water and infrastructure projects. From offices in Abu Dhabi and Dubai we support EPC contractors, electrical contractors, panel builders and plant procurement teams with power, control, instrumentation and fibre optic cables.

Our range covers HV and MV XLPE cables to IEC 60502-2, LV XLPE and PVC power cables to IEC 60502-1 and BS 5467, multicore control cables, panel wire and flexible cables to IEC 60227 and IEC 60245, instrumentation and thermocouple cables, FR, FRLS, LSZH and fire survival cables, and fibre optic cables to IEC 60794.

ADNOC cable supplier and Saudi Aramco cable supplier support

Projects in the UAE, Saudi Arabia and the wider GCC often reference operator specifications, approved manufacturer lists and inspection requirements. Gasify reviews these requirements against the cables you need, coordinates the documentation called for by the order, and supports the RFQ from technical clarification to delivery. Approval status is never assumed. Requirements are confirmed against each project's documents.

HV, MV and LV XLPE power cables

XLPE insulated cables run at 90 °C and withstand 250 °C in a short circuit, so they carry more current and tolerate faults better than PVC cables. Medium voltage cables from 3.6/6 kV to 18/30 kV use a conductor screen, XLPE insulation and an insulation screen with a copper tape or wire metallic screen, while LV cables at 0.6/1 kV are available armoured or unarmoured in copper and aluminium.

Armoured cable, single core and direct burial

Steel wire or strip armour protects multicore cables in direct burial and exposed routes and can serve as the earth continuity path. Single core cables on AC systems need non-magnetic aluminium armour, because magnetic armour overheats from eddy currents.

Control, panel, flexible and VFD cables

Multicore control cables with numbered or coloured cores, single core panel wire, flexible multicore and rubber cables, and screened symmetrical VFD cables cover switchgear, motor control centres, control panels, machinery and drives.

Instrumentation and thermocouple cables

Screened pair and triad instrumentation cables, with intrinsically safe blue sheath options, and thermocouple extension cables for K, J, T, N and E types carry field signals to DCS and SCADA systems.

FRLS, LSZH and fire survival cables

FR and FRLS PVC cables limit flame spread and smoke, LSZH cables remove halogen gas and give low, less toxic smoke, and fire survival cables with glass mica tape keep emergency circuits running in a fire. Solar DC cables, anti-termite and mining cables are available on enquiry.

Cables with glands, lugs, trays and fibre optic in one package

Cables rarely travel alone. Gasify can consolidate cables with cable glands, lugs, trays and earthing materials, fibre optic cables, instrumentation and structural steel in a single package, with phased deliveries to the UAE, GCC, Middle East, Africa and South Asia. Explore how we work on our project supply page or read about oil and gas supply.

11 / FAQ

Power, control and fibre cable questions.

Are you a power cable and control cable supplier in the UAE?

Gasify sources power, control, instrumentation and fibre optic cables from established manufacturers and supports procurement from the UAE. Availability depends on cable type, size, voltage grade, conductor and quantity, so lead times and stock are confirmed for each RFQ.

Can you supply cables to ADNOC and Saudi Aramco project specifications?

Gasify supports procurement against project cable schedules and client specifications, including ADNOC and Saudi Aramco requirements where the project calls for them. Approved manufacturer and vendor list requirements are reviewed for each project. Gasify does not represent an approval status unless it is formally documented.

Which cables do you supply?

The range covers HV and MV XLPE power cables, LV XLPE and PVC power cables, multicore control cables, panel wire, flexible and VFD cables, instrumentation and thermocouple cables, fire-performance and special cables, and fibre optic cables.

What is the difference between XLPE and PVC insulated cables?

XLPE is a cross-linked, thermosetting insulation that runs at 90 °C and withstands 250 °C in a short circuit, so it carries more current and handles faults better. PVC is thermoplastic, runs at 70 °C and costs less. XLPE is preferred for power cables, PVC for general wiring.

Should I choose copper or aluminium conductors?

Copper has higher conductivity and mechanical strength, so a copper cable is smaller for the same current. Aluminium is lighter and costs less for large sizes, but needs correct lugs and bimetallic connectors. Use tinned copper where sulphur fumes can corrode plain copper.

When do I need an armoured cable?

Use armoured cable for direct burial, exposed routes and where mechanical protection is needed, and where the armour must serve as an earth continuity path. Unarmoured cable is enough on protected trays. Single core AC cables need non-magnetic aluminium armour.

What is the difference between FR, FRLS, LSZH and fire survival cable?

FR cable limits flame spread. FRLS cable adds lower smoke emission, but it is still PVC, so some smoke and halogen gas remain. LSZH cable has no halogen and gives low, less toxic smoke. Fire survival cable keeps the circuit working for a stated time in a fire.

What is the difference between IEC and IS voltage grades?

IEC grades such as 3.6/6 kV and 18/30 kV and Indian Standard grades such as 3.8/6.6 kV and 19/33 kV describe similar classes of cable. The first value is the voltage to earth and the second is between conductors. State the standard in the RFQ so the correct insulation thickness is supplied.

What cable goes between a variable frequency drive and a motor?

A screened, symmetrical VFD cable, with the screen terminated at both ends, reduces electromagnetic interference and bearing currents. Cable length and drive switching frequency affect the choice.

How do I check the short-circuit rating of a cable?

Compare the fault current and clearing time with the conductor's adiabatic withstand, which depends on the conductor material, the insulation and the cross-section. Use the calculator on this page for a quick check, and confirm with the project cable sizing calculation.

What tests and certificates come with the cables?

Cables come with routine test reports for each drum. Type-test reports for fire, smoke and construction, partial discharge tests for MV cables, third-party inspection and EN 10204-type certification of metal accessories can be arranged where the project specifies them.

How do I request a quotation for cables?

Send your cable schedule or BOQ with voltage grade, standard, conductor material and size, number of cores, armour, sheath type and fire performance, drum length, quantity, required tests and delivery location. The procurement team reviews the requirement and responds with a quotation.

Do you deliver outside the UAE?

Yes. Gasify coordinates delivery from the UAE to the GCC, wider Middle East, Africa and South Asia, subject to product, quantity, destination and logistics requirements. Include the delivery location in your RFQ.

12 / START A REQUIREMENT

Send your cable schedule. We'll build the supply route.

Share your cable schedule, BOQ or datasheets with the delivery location. Our procurement team will review voltage grades, constructions, fire performance and documentation, then coordinate sourcing, quotation and delivery.

PHONE / WHATSAPP+971 58 580 9068
SERVINGUAE · GCC · Middle East · Africa · South Asia