Electrical Accessories Supplier & Stockist UAE | Cable Glands, Trays, Cables | Gasify
PRODUCTS · ELECTRICAL ACCESSORIES · SUPPLIER & STOCKIST · UAE

Industrial Electrical Supply Partner for EPC & Energy Infrastructure

Gasify Middle East supplies cable glands, cable trays and ladders, conduits and fittings, junction boxes and enclosures, power, control and instrumentation cables, lugs and terminations, and earthing materials from Abu Dhabi and Dubai. Industrial and Ex-certified products to IEC, ATEX and IECEx requirements, supplied against your MTO or datasheet with certificates and traceability.

Built for project procurement: we match each item to the area classification, cable and enclosure, confirm sources against your project specification, and support ADNOC, Saudi Aramco and other client-specification enquiries across the UAE, GCC, Middle East, Africa and South Asia.

IEC 60079ATEX / IECExEN 62444IEC 61537IEC 60502-1BS 5467IEC 62305EN 10204 3.1
01 / ELECTRICAL RANGE

Environment-Rated Accessories Engineered to Your Cable Specifications

From Ex cable glands and junction boxes to trays, cables, lugs and earthing, sourced against area classification, standard and project specification.

Cable Glands & Accessories — Gasify Middle East electrical supplyELECTRICAL · 01
01PROJECT SUPPLY

Cable Glands & Accessories

Industrial and Ex-certified cable glands for armoured and unarmoured cable, with lock nuts, earth tags, shrouds, adaptors and stopping plugs.

Ex d / Ex eIP66 / IP68Brass / SS316
Cable Trays, Ladders & Supports — Gasify Middle East electrical supplyELECTRICAL · 02
02PROJECT SUPPLY

Cable Trays, Ladders & Supports

Perforated trays, ladder racks, wire mesh trays and support systems in galvanised, stainless steel, aluminium and GRP.

Ladder / perforatedHDG / SS316 / GRPIEC 61537
Conduits & Conduit Fittings — Gasify Middle East electrical supplyELECTRICAL · 03
03PROJECT SUPPLY

Conduits & Conduit Fittings

Rigid steel, flexible and PVC conduit with couplings, bends, boxes and sealing fittings for exposed wiring runs.

Rigid GIFlexibleEx seals
Junction Boxes & Enclosures — Gasify Middle East electrical supplyELECTRICAL · 04
04PROJECT SUPPLY

Junction Boxes & Enclosures

Terminal and junction boxes, control stations and enclosures in GRP, stainless steel and aluminium, with Ex e, Ex d and Ex i options.

Ex e / Ex d / Ex iGRP / SS / AluIP66
Power, Control & Instrumentation Cables — Gasify Middle East electrical supplyELECTRICAL · 05
05PROJECT SUPPLY

Power, Control & Instrumentation Cables

LV armoured power cables, control cables and screened instrumentation cables, including LSZH and fire-resistant types.

XLPE / SWALSZHFire resistant
Lugs, Connectors & Terminations — Gasify Middle East electrical supplyELECTRICAL · 06
06PROJECT SUPPLY

Lugs, Connectors & Terminations

Crimp and bimetallic lugs, connectors, terminal blocks, heat-shrink sleeves, cable ties and cable markers.

Crimp lugsBimetallicTerminals
Earthing & Lightning Protection — Gasify Middle East electrical supplyELECTRICAL · 07
07PROJECT SUPPLY

Earthing & Lightning Protection

Earth rods, copper tape, clamps, exothermic weld kits, inspection pits and lightning protection components.

Earth rodsCopper tapeIEC 62305
Hazardous-Area Lighting & Power Accessories — Gasify Middle East electrical supplyELECTRICAL · 08
08PROJECT SUPPLY

Hazardous-Area Lighting & Power Accessories

Ex-certified LED luminaires, plugs, sockets, switches and small power distribution items, sourced to the area classification on enquiry.

Ex LEDPlugs / socketsATEX / IECEx
02 / SPECIFICATIONS

Product data tables and standard compliance.

Typical supply ranges. Availability depends on product, size, rating and quantity, and is confirmed for every RFQ.

ProductStandardMaterial / typeSize & ratingTypical use
Industrial cable gland, armoured (BW / CW)EN 62444; BS 6121Nickel-plated brass, stainless steel 316, aluminiumM16 to M100, PG, NPT or BSP threads; IP66 / IP68Termination of SWA and braided cable in non-hazardous areas
Industrial cable gland, unarmouredEN 62444Nickel-plated brass, SS316, nylonM12 to M63; IP66 / IP68Control and instrument cable entries
Ex d (flameproof) cable glandIEC 60079-0 / -1; EN 62444Nickel-plated brass, SS316; barrier type for Ex dM20 to M100, NPT; Ex db IIC Gb (typical)Zone 1 and Zone 2 flameproof enclosures
Ex e (increased safety) cable glandIEC 60079-0 / -7; EN 62444Nickel-plated brass, SS316, polyamideM20 to M100, NPT; Ex eb IIC Gb (typical)Zone 1 and Zone 2 junction and terminal boxes
Dust-ignition proof cable glandIEC 60079-31Brass, SS316IP66 / IP68; Ex tb IIIC Db (typical)Zone 21 and Zone 22 dust areas
Cable gland with compression seal for lead or marine cableBS 6121; manufacturer standardBrass, SS316Per cable ODMarine and offshore cables
Gland accessoriesManufacturer standardBrass, SS, nylon, EPDMLock nuts, earth tags, shrouds, entry thread adaptors, reducers, stopping plugs, blanking plugsCompleting and sealing cable entries

State cable OD, armour type, thread (metric, NPT, PG or BSP), protection type, gas group, zone and material in the RFQ. The gland certificate and the enclosure certificate must both cover the installation.

ProductStandardMaterial / typeSize & ratingTypical use
Perforated cable trayIEC 61537; NEMA VE 1HDG steel (ISO 1461), SS316, aluminium, GRPWidth 50 to 900 mm; depth 25 to 150 mmMedium cable loads and good ventilation
Ladder cable trayIEC 61537; NEMA VE 1HDG steel, SS316, aluminium, GRPWidth 150 to 900 mm; depth 50 to 150 mmHeavy power cable runs and long spans
Wire mesh cable trayIEC 61537Pre-galvanised, HDG, SS316Width 50 to 600 mmLight-duty, data and commercial runs
Trunking and cable ductIEC 61084Steel, PVCPer profileEnclosed routing of small cable bundles
Tray fittingsIEC 61537As per trayBends, tees, crosses, reducers, risers, couplers and coversChanges in direction, branches and covers
Support systems and strut channelManufacturer standardHDG, SS316, GRPStrut channel, brackets, hangers, base plates, threaded rodMounting trays, conduit and equipment
Cleats and cable tiesIEC 61914; manufacturer standardSS316, PA66, HDG steelPer cable ODSecuring cables on trays and structures

Tray load class, span, finish and cover requirements follow the manufacturer's load table. State width, depth, thickness and finish in the RFQ.

ProductStandardMaterial / typeSize & ratingTypical use
Rigid steel conduit (GI)IEC 61386-21; ANSI C80.1Galvanised steel; threaded ends to ASME B1.20.11/2 in to 6 in (20 to 150 mm)Mechanical protection of exposed wiring
IMC / EMT conduitANSI C80.6 / C80.3Galvanised steel1/2 in to 4 inLighter-duty indoor runs
Flexible metallic conduit and liquid-tight conduitIEC 61386-23; UL 360GI, SS316, PVC jacketed1/2 in to 4 inFinal connections to motors and instruments
PVC rigid conduitIEC 61386-21PVC16 to 63 mmNon-corrosive, buried and concealed runs
Conduit fittingsIEC 61386; manufacturer standardGI, aluminium, SS316, PVCCouplings, elbows, tees, boxes, unions, clampsCompleting conduit systems
Ex conduit seals and drainsIEC 60079-1; manufacturer standardCast aluminium, SS316, GISealing fittings with compound; drain and breatherEx d conduit systems and zone boundary sealing

Include conduit type, size, thread standard, finish and the required seals or drains at hazardous area boundaries.

ProductStandardMaterial / typeSize & ratingTypical use
Ex e terminal and junction boxIEC 60079-0 / -7GRP, stainless steel 316, aluminium (copper-free or low copper)Sizes per datasheet; IP66; Ex eb IIC GbZone 1 and Zone 2 field junctions
Ex d flameproof enclosureIEC 60079-0 / -1Cast aluminium, SS316Per datasheet; IP66; Ex db IIC GbZone 1 instrument, switch and starter housings
Ex i intrinsically safe junction boxIEC 60079-0 / -11GRP or SS316; blue enclosurePer datasheet; IP66Intrinsically safe loops in Zone 0, 1, 2
Control stations and push buttonsIEC 60079; IEC 60947-5-1GRP, SS316, aluminiumSingle and multi-wayLocal start, stop and emergency stop
Industrial junction box, non-ExIEC 62208; IEC 60529GRP, SS316, polycarbonate, mild steelIP66 / IP67; NEMA 4XSafe areas and utility junctions
Ex luminaire, LEDIEC 60079; IEC 60598Aluminium, SS316; glass diffuserEx db / eb / mb; IP66 / IP67Area lighting and emergency lighting in hazardous areas
Plugs, sockets and switches, Ex and industrialIEC 60309; IEC 60079Aluminium, SS316, GRP, polyamide16 A to 125 A; 2P+E, 3P+E, 3P+N+EPortable tool and maintenance power

State the Ex protection type, gas group, temperature class, zone, IP rating and entry details. Ex equipment is supplied with the manufacturer's certificate, and Gasify does not certify equipment itself.

ProductStandardMaterial / typeSize & ratingTypical use
LV power cable, XLPE / SWA / PVCIEC 60502-1; BS 5467Cu or Al conductor; XLPE insulation; SWA armour; PVC sheath0.6/1 kV; 1.5 to 400 mm²; 1 to 5 corePower distribution to motors, panels and loads
LV power cable, XLPE / SWA / LSZHBS 6724; IEC 60502-1Cu or Al conductor; XLPE; SWA; LSZH sheath0.6/1 kV; 1.5 to 400 mm²Enclosed areas, offshore and public buildings
Fire-resistant cableIEC 60331; BS 7846Cu conductor, mica tape, XLPE, LSZH0.6/1 kV; per sizeEmergency lighting, fire alarm and life-safety circuits
Control cable, multicoreIEC 60502-1; client specificationCu stranded conductor, XLPE or PVC, SWA1.5 and 2.5 mm²; up to 61 coreMotor control and signalling
Instrumentation cable, pairs / triadsEN 50288; client specificationCu conductor, individual and overall screen, SWA, PVC or LSZH0.5 to 1.5 mm²; 1 to 48 pairsAnalogue and digital field signals
Flexible and trailing cableIEC 60245; IEC 60227Cu flexible conductor, rubber or PVC0.75 to 240 mm²Portable equipment and mobile machinery
Medium voltage cableIEC 60502-2Cu or Al, XLPE, screened and armoured3.6/6 kV to 18/30 kVMV distribution on enquiry

State the voltage grade, conductor material and size, number of cores or pairs, armour, sheath type, fire performance and drum length. Cable is supplied on drums and cut to length on enquiry.

ProductStandardMaterial / typeSize & ratingTypical use
Copper tubular crimp lugDIN 46235; IEC 61238-1Tinned electrolytic copper6 to 630 mm²; M5 to M20 studTerminations on copper conductors
Bimetallic lug (Al to Cu)IEC 61238-1Aluminium barrel, copper palm16 to 400 mm²Aluminium conductors onto copper busbars
Pin and ferrule terminalsDIN 46228Tinned copper, insulated and bare0.5 to 50 mm²Control and instrument wiring
Terminal blocksIEC 60947-7-1Polyamide, brass or copper2.5 to 240 mm²Terminal strips in panels and junction boxes
Heat-shrink sleeves and cable markersManufacturer standardCross-linked polyolefinPer cable ODInsulation, sealing and identification
Earth rods and accessoriesIEC 62561-2; BS 7430Copper-bonded steel, SS, solid copper3/4 in x 3 m typical; 14 to 25 mm diaEarth electrodes for grounding grids
Copper tape, clamps and exothermic weldsIEC 62561; IEEE 80Bare copper tape, bronze clamps, exothermic moulds25 x 3 mm to 50 x 6 mmEarthing grid conductors and joints
Lightning protection air terminals and conductorsIEC 62305; IEC 62561Copper, aluminium, galvanised steel, SSRods, down conductors, test jointsStructure lightning protection systems

Match lug barrel size to conductor cross-section and palm hole to the stud size. Use bimetallic parts where aluminium meets copper.

Protection types

MarkingProtection typeHow it worksTypical zones
Ex dFlameproof enclosureContains an internal explosion and prevents flame transmissionZone 1, 2 (Gb); gas
Ex eIncreased safetyPrevents arcs, sparks and hot surfacesZone 1, 2 (Gb); gas
Ex i (ia / ib / ic)Intrinsic safetyLimits energy so the circuit cannot ignite the atmosphereia: Zone 0, 1, 2 (Ga); ib: Zone 1, 2 (Gb); ic: Zone 2 (Gc)
Ex n / Ex ecNon-sparkingNot-incendive operation in normal conditionsZone 2 (Gc); gas
Ex pPressurisationProtective gas keeps the atmosphere outZone 1, 2; gas
Ex mEncapsulationEncloses parts in compoundZone 0, 1, 2 depending on level
Ex tDust protection by enclosureDust-tight enclosure with surface temperature limitZone 20, 21, 22 (Da, Db, Dc); dust

Reading Ex, IP and IK markings

ItemValuesNotes
Gas groupIIA (propane), IIB (ethylene), IIC (hydrogen, acetylene)IIC covers IIB and IIA; IIB covers IIA
Temperature classT1 450 °C, T2 300 °C, T3 200 °C, T4 135 °C, T5 100 °C, T6 85 °CSurface temperature must stay below the gas auto-ignition temperature
Equipment protection level (EPL)Ga, Gb, Gc (gas); Da, Db, Dc (dust); Ma, Mb (mines)Maps to the zone in which equipment may be used
ZonesZone 0, 1, 2 (gas); Zone 20, 21, 22 (dust)Set by the area classification drawing
Ingress protection (IP)IP65 dust-tight and jet-proof; IP66 powerful jets; IP67 temporary immersion; IP68 continuous immersionIEC 60529
Impact protection (IK)IK07 (2 J), IK08 (5 J), IK09 (10 J), IK10 (20 J)IEC 62262
Marking exampleEx db eb IIC T6 Gb IP66Certificate number ends with X when special conditions of use apply

General guide only. The area classification drawing and the equipment certificates decide what is suitable for each zone.

Cross-sectionMax DC resistance, Cu at 20 °C (Ω/km)Cu at 90 °C (Ω/km)Al at 90 °C (Ω/km)
1.5 mm²12.115.42925.597
2.5 mm²7.419.44815.676
4 mm²4.615.8789.752
6 mm²3.083.9276.516
10 mm²1.832.3333.871
16 mm²1.151.4662.433
25 mm²0.7270.9271.538
35 mm²0.5240.6681.109
50 mm²0.3870.4930.819
70 mm²0.2680.3420.567
95 mm²0.1930.2460.408
120 mm²0.1530.1950.324
150 mm²0.1240.1580.262
185 mm²0.09910.1260.210
240 mm²0.07540.0960.160
300 mm²0.06010.0770.127

Copper values are the maximum DC resistance of plain copper class 2 conductors in IEC 60228. The 90 °C values apply a temperature coefficient of 0.00393 for copper and 0.00403 for aluminium, and aluminium also uses a 1.65 resistivity ratio. These are the values the voltage drop calculator uses.

03 / MATERIALS & FINISHES

Environment-matched materials and corrosion protection.

The Gulf's coastal, humid and dusty conditions make material and finish as important as the rating.

MaterialTypical productsSuitable forNotes
Nickel-plated brassCable glands, adaptors, plugsIndustrial and onshore areasGood general corrosion resistance, not for heavy marine or chemical exposure
Stainless steel 316 / 316LGlands, enclosures, trays, clamps, fittingsOffshore, coastal, chemical and washdownHigher cost, best corrosion resistance for the Gulf environment
Aluminium (copper-free or low copper)Enclosures, luminaires, glands, traysIndustrial and Ex enclosuresLightweight, suited to Ex when the alloy limits for the zone are met
Hot-dip galvanised steel (ISO 1461)Trays, ladders, support steel, conduitOutdoor and industrial areasZinc coating protects steel, cut edges need touch-up
GRP (glass-reinforced polyester)Enclosures, trays, supportsCorrosive, coastal and chemical areasNon-conductive, needs UV stabilisation and anti-static grades in Ex areas
PVC and polyamideConduit, glands, junction boxesNon-hazardous indoor and light outdoor useLimited temperature and UV resistance, not for Ex equipment unless certified
Copper and bimetallicLugs, earth rods, tape, barsConductors and earthingUse bimetallic parts where aluminium and copper meet

General guidance only. The corrosivity category, hazardous area classification and project specification decide the final material.

04 / ELECTRICAL SELECTION GUIDE

Precision matching from cable to enclosure.

A quick reference for common electrical needs. Final selection follows the project specification, area classification drawings and cable schedule.

Installation needProductTypical materialStandardNotes
Terminate armoured cable at a non-hazardous junction boxIP66 / IP68 armoured cable gland with earth tagNickel-plated brass or SS316EN 62444Match thread, cable OD and armour type (BW or CW)
Terminate cable at a Zone 1 or Zone 2 enclosureEx d or Ex e certified gland, matching the enclosure protectionBrass or SS316IEC 60079-0 / -1 / -7The gland certificate and the enclosure certificate must both permit the entry
Offshore or coastal area with salt spraySS316 or GRP enclosures, SS316 trays and glandsSS316, GRPISO 12944 C5; IEC 61537Avoid mixing dissimilar metals, which causes galvanic corrosion
Heavy power cable run over long spanHDG ladder tray with covers and supportsHDG steelIEC 61537Check the load and span against the manufacturer's load table
Mechanical protection on a short exposed runRigid GI conduit with fittingsGI steelIEC 61386; ANSI C80.1Use Ex seals at zone boundaries and enclosure entries
Field instrument junction in a hazardous areaEx e junction box, or Ex i box for intrinsically safe loopsGRP, SS316IEC 60079-7 / -11Keep Ex i cabling separate from non-Ex i wiring
Power distribution to motors and panelsXLPE / SWA / PVC cable, 0.6/1 kVCu or AlIEC 60502-1; BS 5467Size for current, voltage drop and short circuit
Enclosed area, offshore or public buildingLSZH cableCu, XLPE, LSZHBS 6724; IEC 60332Low smoke and low halogen emission in fire
Life-safety circuits that must work in a fireFire-resistant cable and fire-rated supportsCu, mica, LSZHIEC 60331; BS 7846Circuit integrity depends on correct supports and glands
Aluminium conductor terminated onto copper barBimetallic lugAl barrel, Cu palmIEC 61238-1Do not use standard copper lugs on aluminium conductors
Area lighting in a classified areaEx-certified LED luminaireAluminium, SS316IEC 60079; IEC 60598Match gas group, temperature class and zone
05 / CABLE VOLTAGE DROP CALCULATOR

Verify cable sizing and voltage drop limits before requesting a quote.

Voltage drop from current, length, conductor size, material and power factor, with the smallest size that stays within your limit.

ΔV = k × I × L × (R cosφ + X sinφ)
k = √3 (three-phase), 2 (single-phase); X ≈ 0.08 Ω/km

VOLTAGE DROP0.0V
VOLTAGE DROP AS % OF SUPPLY0.00%
RESULT AGAINST LIMIT—
SMALLEST SIZE WITHIN LIMIT (VOLTAGE DROP ONLY)—

A first-pass check only. It does not check current-carrying capacity, installation method, grouping, ambient temperature, short-circuit withstand or motor starting. Reactance is a typical value. Confirm against the project cable sizing calculation. Send the cable and accessories list for a quotation →

06 / ADNOC & SAUDI ARAMCO PROJECT SUPPLY

Compliant with ADNOC & Saudi Aramco project standards.

Major NOC and EPC projects define the certification, material, testing and vendor requirements. We work to those documents.

SPECIFICATION REVIEW

From MTO to a compliant quotation.

Before quoting, we check the enquiry against the documents that drive electrical compliance on NOC-linked projects.

  • Material requisition, MTO, cable schedule and datasheet review
  • Area classification, protection type, gas group, temperature class and zone
  • Client and company specification requirements, including ADNOC and Saudi Aramco documents where the project calls for them
  • Approved manufacturer or vendor list (AVL) requirements for the proposed source
  • Fire performance, LSZH, material and coating clauses
INSPECTION & DOCUMENTATION

Certificates that travel with the product.

Documentation follows the purchase order and the project specification, with clear traceability.

  • ATEX or IECEx certificates and marking for Ex equipment
  • Type-test, IP and cable routine test reports
  • EN 10204 3.1 material certificates, and 3.2 where specified
  • Third-party inspection coordination where the project requires it
  • Packing list and shipping documents compiled for the client's records
Important: Gasify supports procurement against ADNOC, Saudi Aramco and other client specifications. Product compliance, approved-source requirements and documentation are reviewed for each project, and Gasify does not represent an approval or vendor-registration status.
07 / STANDARDS & CODES

Global certifications behind every order.

HAZARDOUS AREA

IEC 60079 · ATEX · IECEx

Explosion protection of electrical equipment, certified by notified bodies.

INGRESS & IMPACT

IEC 60529 · IEC 62262 · NEMA 250

IP, IK and NEMA enclosure ratings.

CABLE GLANDS

EN 62444 · BS 6121

Cable glands for electrical installations and hazardous areas.

CABLE TRAYS

IEC 61537 · NEMA VE 1

Cable tray and ladder systems and their load classification.

CONDUIT

IEC 61386 · ANSI C80.1

Conduit systems for cable management.

POWER CABLES

IEC 60502-1 · BS 5467 · BS 6724

LV armoured cables, including LSZH.

CONDUCTORS

IEC 60228

Conductor classes, sizes and resistance.

INSTRUMENTATION CABLES

EN 50288

Multi-element cables for analogue and digital signals.

FIRE PERFORMANCE

IEC 60332 · IEC 60331 · IEC 61034

Flame propagation, circuit integrity and smoke density.

LUGS & CONNECTORS

IEC 61238-1 · DIN 46235

Compression and mechanical connectors and crimp lugs.

EARTHING & LIGHTNING

IEC 62305 · IEC 62561 · BS 7430

Lightning protection, component and earthing practice.

CERTIFICATION

EN 10204 3.1 · Ex certificates

Material certificates, type-test reports and Ex certification.

08 / TESTING & DOCUMENTATION

Every certificate and test parameter confirmed before PO.

Tests and documents depend on the product standard, purchase order and applicable project specification.

✓

Ex certificate verification

Check of ATEX or IECEx certificates, marking, schedule of limitations and special conditions against the area classification.

✓

Type-test and IP reports

IP, IK, flame and temperature-rise type-test reports from the manufacturer for the delivered model.

✓

Cable routine tests

Conductor resistance, high-voltage and insulation resistance tests on cable drums, with the test report per IEC 60502-1.

✓

Material & coating checks

EN 10204 3.1 material certificates, galvanising thickness to ISO 1461 and stainless steel grade verification.

✓

Dimensional & visual inspection

Gland threads, tray widths, enclosure dimensions, finish and marking against the order.

✓

Inspection, packing & TPI

Third-party inspection coordination, drum and crate packing, and shipping documents.

09 / APPLICATIONS

Powering High-Stakes Operations.

01

Oil & gas hazardous areas

Ex-certified glands, junction boxes, luminaires and cables for Zone 1 and Zone 2.

02

Refining & petrochemical

Cable trays, cables, glands and enclosures for process and utility areas.

03

Offshore & marine

SS316 and GRP products, LSZH and fire-resistant cables.

04

Power generation

Cables, trays, earthing and lugs for power plant and substations.

05

LNG & cryogenic

Ex equipment and cables suited to cold service and terminals.

06

Water & desalination

Corrosion-resistant enclosures, trays and cables for water plants.

07

Industrial plants & skids

Junction boxes, cables and accessories for skids and packaged units.

08

Construction & infrastructure

Conduits, trays, cables and earthing for buildings and utilities.

10 / WHY GASIFY

Procurement accountability from specification to site handover.

CATALOGUE-STYLE SUPPLY
  • Quotation against a product list, with Ex protection, zone and thread left to the buyer
  • Gland and enclosure certificates that do not match found at site
  • Cables, glands, trays and lugs quoted separately
  • Approved-source requirements discovered late in the process
ELECTRICAL PROCUREMENT WITH GASIFY
  • MTO and datasheets reviewed, with protection type, zone, thread and material matched before quotation
  • Certificate, test report and TPI requirements aligned with the order
  • Cables, glands, trays, enclosures and lugs consolidated in one package
  • AVL and vendor requirements checked at quotation stage
01

RFQ response support

Send an MTO or datasheet and the procurement team reviews scope, ratings and documentation before quoting.

02

UAE stock and global manufacturers

Stock support from the UAE combined with manufacturer sourcing for non-stock and project-specific items.

03

Shutdown & turnaround supply

Schedule-driven supply for plant maintenance, shutdown and emergency electrical requirements.

11 / ELECTRICAL SUPPLIER IN THE UAE

Electrical accessories supplier and stockist in Abu Dhabi and Dubai.

Gasify Middle East Trading LLC is a UAE-based industrial supplier and stockist of electrical accessories, including cable glands, cable trays, conduits, junction boxes, cables, lugs and earthing materials. From offices in Abu Dhabi and Dubai we support EPC contractors, electrical contractors, skid packagers and plant procurement teams in oil and gas, petrochemical, refining, power generation, water and infrastructure.

Our electrical range covers industrial and Ex-certified cable glands to EN 62444 and IEC 60079, cable trays and ladders to IEC 61537, conduit systems to IEC 61386, junction boxes and enclosures, LV armoured cables to IEC 60502-1 and BS 5467, instrumentation cables, crimp and bimetallic lugs, and earthing and lightning protection components.

ADNOC electrical supplier and Saudi Aramco electrical supplier support

Projects in the UAE, Saudi Arabia and the wider GCC often reference ADNOC or Saudi Aramco specifications, approved manufacturer lists and inspection requirements. Gasify reviews these requirements against the products you need, coordinates the documentation called for by the order, and supports the RFQ from technical clarification to delivery. Approval status is never assumed. Requirements are confirmed against each project's documents.

Ex cable glands, junction boxes and hazardous-area equipment

Ex d and Ex e cable glands, Ex e and Ex i junction boxes, control stations, Ex LED luminaires and plugs and sockets are sourced to the area classification of the site: protection type, gas group, temperature class and zone. The gland and the enclosure must both be certified for the installation, and certificates are supplied by the manufacturer.

Cable trays, ladders, conduits and supports

Ladder, perforated and wire mesh trays and strut support systems are available in hot-dip galvanised steel, stainless steel 316, aluminium and GRP. Rigid, flexible and PVC conduits with fittings and Ex sealing fittings cover exposed wiring runs in industrial areas.

Power, control and instrumentation cables

LV XLPE/SWA cables in PVC and LSZH sheaths, fire-resistant cables, control cables and screened instrumentation cables are available in copper and aluminium conductors, on drums and cut to length on enquiry. Use the voltage drop calculator on this page for a first check of cable size.

Lugs, terminations, earthing and lightning protection

Crimp and bimetallic lugs, terminal blocks, heat-shrink sleeves, earth rods, copper tape, exothermic weld kits and lightning protection components complete the installation.

Electrical accessories with pipes, instruments and structural steel in one package

Electrical items rarely travel alone. Gasify can consolidate electrical accessories with instrumentation, structural steel, steel pipes, flanges and valves in a single package, with phased deliveries to the UAE, GCC, Middle East, Africa and South Asia. Explore how we work on our project supply page or read about oil and gas supply.

12 / FAQ

Electrical supply questions.

Are you an electrical accessories supplier and stockist in the UAE?

Gasify combines UAE-based supplier and stockist support with manufacturer sourcing. Availability depends on product, size, rating and quantity, so current stock is confirmed for each RFQ.

Can you supply electrical accessories to ADNOC and Saudi Aramco project specifications?

Gasify supports procurement against project material requisitions and client specifications, including ADNOC and Saudi Aramco requirements where the project calls for them. Approved manufacturer and vendor list requirements are reviewed for each project. Gasify does not represent an approval status unless it is formally documented.

Which electrical products do you supply?

The range covers cable glands and accessories, cable trays, ladders and supports, conduits and fittings, junction boxes and enclosures, power, control and instrumentation cables, lugs and terminations, earthing and lightning protection, and Ex-certified lighting and power accessories on enquiry.

What is the difference between Ex d and Ex e cable glands?

An Ex d gland is used with a flameproof enclosure and often has a barrier or compound seal that stops flame passing along the cable. An Ex e gland is used with increased-safety enclosures and seals against ingress. The gland must be certified for the protection type of the enclosure it enters.

What does an Ex marking such as Ex db eb IIC T6 Gb mean?

It lists the protection types (flameproof d, increased safety e), the gas group (IIC), the temperature class (T6, surface at or below 85 °C) and the equipment protection level (Gb, for Zone 1). Equipment must match the area classification of the site.

What do IP66 and IP68 mean?

The first digit shows protection against solids and the second shows protection against water. IP66 is dust-tight and withstands powerful water jets. IP68 is dust-tight and suitable for continuous immersion under conditions agreed with the manufacturer.

Should I choose a ladder tray or a perforated tray?

Ladder trays suit heavy power cables and long spans, and perforated trays suit medium loads and give support along the full cable length. Check the load and span against the tray manufacturer's load table, and select the finish for the environment.

Hot-dip galvanised, stainless steel or GRP for trays and enclosures?

Hot-dip galvanised steel suits most outdoor industrial areas. Stainless steel 316 and GRP suit coastal, offshore and chemical areas. The choice depends on the corrosivity category, the design life and the project specification.

What is the difference between PVC, LSZH and fire-resistant cable?

PVC cable is the standard general-purpose sheath. LSZH cable emits low smoke and no halogens in a fire, which suits enclosed spaces. Fire-resistant cable keeps the circuit working for a stated time in a fire under IEC 60331 or BS 7846. A cable can be LSZH and fire-resistant.

How do I size a cable for voltage drop?

Voltage drop depends on the current, length, conductor size and material, power factor and operating temperature. Use the voltage drop calculator on this page for a first check. Current rating, short-circuit withstand and installation conditions also decide the final size.

What tests and certificates come with the products?

Cables come with routine test reports, and metal products with EN 10204 3.1 material certificates. Ex products come with ATEX or IECEx certificates, and IP and type-test reports are available from the manufacturer. EN 10204 3.2 certification and third-party inspection can be coordinated where specified.

How do I request a quotation for electrical accessories?

Send your MTO, BOQ or datasheet with product type, size, rating, material, Ex protection and zone requirements, standard, quantity, required certificates and delivery location. The procurement team reviews the requirement and responds with a quotation.

Do you deliver outside the UAE?

Yes. Gasify coordinates delivery from the UAE to the GCC, wider Middle East, Africa and South Asia, subject to product, quantity, destination and logistics requirements. Include the delivery location in your RFQ.

13 / START A REQUIREMENT

Send your electrical list. We'll build the supply route.

Share your MTO, BOQ, cable schedule or datasheets with the delivery location. Our procurement team will review products, ratings and documentation, then coordinate sourcing, quotation and delivery.

PHONE / WHATSAPP+971 58 580 9068
SERVINGUAE · GCC · Middle East · Africa · South Asia